1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | 31 | 32 | 33 | 34 | 35 | 36 | 37 | 38 | 39 | 40 | 41 | 42 | 43 | 44 | 45 | 46 | 47 | 48 | 49 | 50 | 51 | 52 | 53 | 54 | 55 | 56 | 57 | 58 | 59 | 60 | 61 | 62 | 63 | 64 | 65 | 66 | 67 | 68 | 69 | 70 | 71 | 72 | 73 | 74 | 75 | 76 | 77 | 78 | 79 | 80 | 81 | 82 | 83 | 84 | 85 | 86 | 87 | 88 | 89 | 90 | 91 | 92 | 93 | 94 | 95 | 96 | 97 | 98 | 99 | 100 | 101 | 102 | 103 | 104 | 105 | 106 | 107 | 108 | 109 | 110 | 111 | 112 | 113 | 114 | 115 | 116 | 117 | 118 | 119 | 120 | 121

THE ENERGY FUTURE OF EXISTING BUILDINGS IN BRUSSELS: BETWEEN PRESERVATION AND PERFORMANCE

Area to be improvedPerformance before improvements [W/m2.K]ImprovementPerformance after improvements [W/m2.K]
Sloped roof1.03Interior insulation0.33
Façades1.60Exterior insulation0.58
Dormer front2.45Exterior insulation0.78
Board above1.97Insulation under0.40
cellar Wood, single glazing5.24Version A: replaced with laminated glass (Ug=3.4 W/m2.K) / panel3.16
Version B: replaced with double glazing (Ug=1.9 W/m2.K) / panel1.99
Back door4.23Version A: replaced with laminated glass (Ug=3.4 W/m2.K) / panel2.81
Version B: replaced with double glazing (Ug=1.9 W/m2.K) / panel2.38
Veranda roof2.26Heated roof system0.58
Attic roof1.92Insulation of the wooden floor in the attic0.81
Veranda façades2.84Exterior insulation0.70
AirtightnessBad v50 = 12m3/h.m2Improve airtightnessGood5 v50 = 3m3/h.m2
HeatingEfficiency: 65.40%No improvement realisedEfficiency: 83.02%
LightingSeveral incandescent light bulbsReplace incandescent light bulbs with LEDsOnly low-energy light bulbs
VentilationNo ventilation systemNatural air supply and extraction via the wet areas+/- System C

Table 2

Measures Kruisbooglaan 34 (© Cenergie).